Amplifier Analyzer AOIP Bài giảng LabView Balance Bản tin công nghệ Biến tần-Khởi động mềm blogger_ino Calibrator Cảm biến chuyên dụng Takex DX-S35F – DX-S33C – Phase Diffrential Detection BGS Sensors – Takex Việt Nam Cảm biến quang AECO FT18SM-CP50 – Photoelectric Sensors AECO – AECO Viet Nam Cảm biến quang AECO FTQSP – Photoelectric Sensors AECO – AECO Viet Nam Cảm biến quang IFM – Photoelectric Sensor IFM O1D100 – IFM Việt Nam – INO Việt Nam Cảm biến siêu âm Takex US-1AH / US-1AHPN – Ultrasonic Sensers – Takex Viet Nam Cảm biến siêu âm Takex US-S25AN – Takex Viet Nam – INO Việt Nam Cảm biến siêu âm Takex US-T04AN – Ultrasonic Sensers – Takex Viet Nam – INO Việt Nam Cảm biến siêu âm Takex US-T50 / US-R25 – Ultrasonic Sensers – Takex Viet Nam – INO Việt Nam Cảm biến siêu âm Takex US-U30AN – Takex Viet Nam – INO Việt Nam Cảm biến siêu âm Takex USA-S1AN / USA-S3MAN / USA-S6AN – Ultrasonic Displacement Sensers – Takex Viet Nam Cảm biến siêu âm Takex VS-S50RNF / VS-S20R / VS-S20B / VS-S15W / VS-S15WNF / VS-S15RBNF – BGS Photodiode Array Sensers – Takex Viet Nam Cảm biến sợi quang Takex F1R – F1RPN – F1RH – F1RHPN – F1RM – F1RMPN – F1RH-J – F11R – F11CR – F11CRPN – Digital Display Fiber Optic Sensors – Takex Viet Nam Cảm biến sợi quang Takex F70RK – F70GK – F70BK – F70WK – F70RKPN – F70GKPN – F70BKPN – F70WKPN – Fiber Optic Sensors – Takex Viet Nam Cảm biến sợi quang Takex F80R – F80RPN – Digital Display Fiber Optic Sensors – Takex Viet Nam Cảm biến vị trí AECO – Cảm biến cảm ứng AECO SMF – M12 – M18 – M30 – Metalface Inductive Sensors – AECO Việt Nam Cảm biến vị trí AECO – Cảm biến điện dung AECO SC18SP – SC30SM – Capacitive Sensors – AECO Việt Nam Cảm biến vị trí AECO – Cảm biến điện dung AECO SC30SP – SC30M – Capacitive Sensors – AECO Việt Nam Cảm biến vị trí AECO – Cảm biến từ AECO SI12SM – Inductive Sensors – AECO Việt Nam Cảm biến vị trí AECO – Cảm biến từ AECO SIP12 – SIQ80 – Inductive Sensors – AECO Việt Nam Controller Counter/Timer Data Acquisition System Dịch vụ Đếm xung và đếm số vòng quay của động cơ bằng encoder ElCO và PLC S7-300 – ELCO Việt Nam Điều Khiển-Giám Sát Đo các đại lượng điện Đo lực-Momen Đo Lường-Kiểm Tra Đo quang-Âm thanh featuredpost featuredpost/sản phẩm Form-Biểu mẫu Giới thiệu Hiệu chuẩn-Cân chỉnh HMI Siemens – Biến Tần Siemens – Simatic Siemens – Module Siemens – Siemens Việt Nam IFTTT Khác Khoảng cách-Vị trí LabView Linh kiện thiết bị khác Lưu lương-Mức Meter Mỹ áp thuế khủng gần 800% lên thép Nga National Instruments – Integrated 266 MHz Real-Time Controller and 2M Gate FPGA (Model: NI cRIO-9073) Nhiệt độ-Áp suất Oscilloscope Phần mềm LabView Phân tích-Thử nghiệm PLC-HMI Power Supply Sản phẩm Sản phẩm - Dự án Sản phẩm nổi bật Sản-phẩm-nổi-bật Sensor Signal Generator Súng bắn nhiệt Fluke – Máy chụp nhiệt Fluke – Fluke Việt Nam – INO Việt Nam Switch Tài liệu LabView Tin tức Tin tức - Sự kiện Tự Động-Đóng Cắt YouTube

Signal Recovery- Current Preamplifier (Model:181)

1033_181
Tên sản phẩm :

Signal Recovery- Current Preamplifier (Model:181)

Mã số : 1033
Hãng sản xuất :
Chủng loại sản phẩm : Amplifier
Ngày cập nhật : 16/10/2013
Giá : Call




Mô tả Sản phẩm

Overview
The model 181 is a current-to-voltage preamplifier of low noise and low input impedance designed to amplify the extremely low currents encountered in such areas as photometry and semiconductor research. In photometric applications the low input noise allows the use of photodetectors with dark currents as low as 10-14 A/√Hz, while the wide frequency range permits high modulation frequencies to avoid 1/f noise and power-line pick-up.

The unit has a high dynamic range, allowing small AC currents to be amplified without overload in the presence of quiescent (DC) detector currents up to ten times the current to voltage converter setting. In semiconductor applications its low input impedance permits the actual bias voltage applied to the device under test to be measured without having to correct for the effects of back bias.

Six switch-selectable sensitivity settings from 10-4 A/V to 10-9 A/V are available and the instrument has a usable frequency range from DC to 200 kHz. A signal monitor connector is provided on the rear panel and there is an overload indicator light on the front panel.

Bias Control
A bias control (accessible through an opening in the bottom of the unit) allows the application of a detector bias voltage at the input connector in the range 0 V to -5 V, with a nominal source impedance of 10-5/S, where S is the selected sensitivity. For example, if the sensitivity is set to 10-7 A/V then the source impedance will be 10-5/10-7, or 100 Ω. In some cases it
may prove convenient to use this bias control to cancel the effect of DC bias accompanying the input signal.

DC Zero Control
A second control, also accessible through an opening in the bottom of the unit, allows the internal electronics to be DC zeroed.

Power
The unit can be powered from an external low voltage, a lock-in amplifier via a suitable power cable, or the models PS0055 or PS0056 remote line power supply modules.


  • Low input impedance
  • Low noise
  • Single-ended virtual ground input
  • Adjustable sensitivity
  • DC to 200 kHz frequency response
  • Detector bias control
  • Photodiode amplification
  • Photomultiplier amplification
  • Ion collector amplification
  • Electron multiplier amplification
Specifications
General
DC coupled current to voltage amplifier with adjustable sensitivity and a maximum frequency response extending from DC to 200 kHz. Adjustable negative detectors bias.  Single-ended virtual ground input and single-ended AC coupled output via BNC connectors.

Powered from external DC power supplies.

DC coupled current to voltage amplifier with adjustable sensitivity and a maximum frequency response extending from DC to 200 kHz. Adjustable negative detectors bias.  Single-ended virtual ground input and single-ended AC coupled output via BNC connectors.Powered from external DC power supplies.

Input
Sensitivity 10-4 A/V to 109 A/V in six angles
Overload Indicator Indicates that instantaneous (DC plus peak AC) current has exceeded amplifier capability - see table below
Frequency Response see table and Figure 1
Input Impedance See Figure 2
Noise Current See Figure 3
Outputs
Monitor Output 600Ω rear-panel BNC connector permits monitoring of the input signal
Main Output
     Level

6.5 V rms maximum
     Impedance 1Ω k nominal
Output Attenuator Provides optional 1:10 attenuation of output voltage
Power ±15 V or ±24 V at 30 mA
General
Dimensions (excluding connectors) 4.5" wide x 6.6" deep x 2.7" high (114 mm wide x 168 mm deep x 69 mm high)
Weight 1.2lbs. (500 g)